Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Evidence dossier
CVE-2023-4346
CVE-2023-4346
gen-56ccdaf9Normalized restatement
KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.
- State
- PUBLISHED
- Published
- Aug 29, 2023
- Updated
- Jul 16, 2026
- Evidence coverage
- 85%
2026-07-18 · v2026.06.15 · percentile 54.3%
Distinct CVSS assessments remain side by side; none are averaged.
Source comparison
Who said what
KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.
KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability
Probability 0.008550000000; percentile 0.542820000000
Applicability
Cited product scope
[{"status": "affected", "version": "0"}]unknowncpe:2.3:a:knx:connection_authorization:-:*:*:*:*:*:*:*supportedAssessments
CVSS by origin
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HLimitations and unknowns
- KEV membership is authoritative for the catalog, not proof of exposure in any environment.
- EPSS is a dated model probability and not an individual-environment prediction.
- Affected or fixed status applies only to the exact cited product and version scope; unresolved scope remains unknown.
- NVD-carried upstream facts remain derivative and are not independent corroboration.
- Only NVD metrics validated under the generation-bound calculator are Public Priority eligible; direct CVE record metrics remain display-only.
- NVD CVSS source eligibility is closed: NVD-authored, exact record-source, or registered same-CVE container origin; unmapped sources remain display-only.
- Factor D is unknown in Public Core because no accepted canonical mapping-obligation ledger is present.
- Core replay supports the active and immediately prior generation; retrospective valid-at replay is deferred.